Structural alteration · UK-wide

Open the space.
Keep the structure secure.

Structural assessment, beam design, calculations and construction details for safe load-bearing wall removals in residential and commercial property.

UK-wideNationwide support
CalculatedTraceable design
PracticalBuildable details
DirectEngineer-led
Alter the layout safely

Removing a wall changes the load path—not just the room.

A load-bearing wall may support floors, roof members, masonry or other structural elements above. The replacement structure must transfer those loads safely to suitable bearings and foundations.

We assess the proposed opening, establish the structural arrangement and prepare a coordinated calculation and drawing package for the agreed Building Regulations scope.

Load-path assessment
Steel or timber beam design
Bearing and support checks
Building Regulations package
What we provide

Structural design from opening review to construction details

The design is based on the verified property arrangement, opening geometry and loads supported above.

01

Structural Review

Assessment of the existing walls, floors, roof and likely load paths around the proposed opening.

02

Beam Design

Steel, timber or other suitable member sized for strength, stability and serviceability.

03

Bearing Checks

End bearings, masonry, piers and padstones checked for the calculated reactions.

04

Support Design

Posts, columns or strengthened supports designed where simple masonry bearing is inadequate.

05

Temporary Stability

Key sequencing and temporary-support requirements identified for safe installation.

06

Calculation Package

Clear calculations and structural details prepared for the agreed approval and construction stage.

Your engineering package

A coordinated wall-removal structural package

The package defines the permanent structure and records the design assumptions used.

A

Structural calculations

Design actions, beam checks, reactions, bearing and stability calculations.

B

Structural details

Beam, padstone, post and connection information for the agreed scheme.

C

Installation notes

Relevant sequence, temporary support and verification requirements.

D

Approval issue

Organised information suitable for the agreed Building Regulations route.

Engineering process

Four clear steps from information to design

01

Share the proposal

Send plans, photographs, opening dimensions and information about the structure above.

02

Inspect & verify

The wall, load paths, supports and relevant site constraints are established.

03

Design the structure

The replacement beam, bearings, posts and connections are calculated.

04

Issue the package

Calculations, details and installation notes are prepared for use.

Key considerations

The checks that control a reliable structural solution

The final design depends on verified geometry, materials, load paths and support conditions.

01

Loads above

Floors, roof, masonry and concentrated reactions must be identified correctly.

02

Existing masonry

Wall thickness, condition and bearing strength affect the support design.

03

Foundations

New posts or high reactions may require verification or local foundation design.

04

Construction sequence

The wall must not be removed before adequate temporary support is installed.

Common questions

Load Bearing Wall Removal, clearly explained

Straight answers about calculations, approvals and starting the work.

How do I know if the wall is load bearing?

The direction of floor and roof members, walls above, foundations and the wider structural arrangement must be assessed. Visual appearance alone is not reliable.

Do I need Building Regulations approval?

Structural alterations normally require Building Regulations approval. The exact route should be confirmed for the property and work.

Can the beam be hidden in the ceiling?

Sometimes, but a flush beam can require deeper coordination with joists, connections, fire protection and construction access.

Will padstones be required?

They may be required where masonry bearing stress or load distribution is inadequate. The calculated beam reactions determine the support detail.

Do you provide installation drawings?

Yes. Structural details and relevant installation notes are included where agreed in the scope.

Ready to move your load bearing wall removal project forward?

Share the drawings, property details and intended work for a clear engineering scope.