Open the space.
Keep the structure secure.
Structural assessment, beam design, calculations and construction details for safe load-bearing wall removals in residential and commercial property.
Removing a wall changes the load path—not just the room.
A load-bearing wall may support floors, roof members, masonry or other structural elements above. The replacement structure must transfer those loads safely to suitable bearings and foundations.
We assess the proposed opening, establish the structural arrangement and prepare a coordinated calculation and drawing package for the agreed Building Regulations scope.
Structural design from opening review to construction details
The design is based on the verified property arrangement, opening geometry and loads supported above.
Structural Review
Assessment of the existing walls, floors, roof and likely load paths around the proposed opening.
Beam Design
Steel, timber or other suitable member sized for strength, stability and serviceability.
Bearing Checks
End bearings, masonry, piers and padstones checked for the calculated reactions.
Support Design
Posts, columns or strengthened supports designed where simple masonry bearing is inadequate.
Temporary Stability
Key sequencing and temporary-support requirements identified for safe installation.
Calculation Package
Clear calculations and structural details prepared for the agreed approval and construction stage.
A coordinated wall-removal structural package
The package defines the permanent structure and records the design assumptions used.
Structural calculations
Design actions, beam checks, reactions, bearing and stability calculations.
Structural details
Beam, padstone, post and connection information for the agreed scheme.
Installation notes
Relevant sequence, temporary support and verification requirements.
Approval issue
Organised information suitable for the agreed Building Regulations route.
Four clear steps from information to design
Share the proposal
Send plans, photographs, opening dimensions and information about the structure above.
Inspect & verify
The wall, load paths, supports and relevant site constraints are established.
Design the structure
The replacement beam, bearings, posts and connections are calculated.
Issue the package
Calculations, details and installation notes are prepared for use.
The checks that control a reliable structural solution
The final design depends on verified geometry, materials, load paths and support conditions.
Loads above
Floors, roof, masonry and concentrated reactions must be identified correctly.
Existing masonry
Wall thickness, condition and bearing strength affect the support design.
Foundations
New posts or high reactions may require verification or local foundation design.
Construction sequence
The wall must not be removed before adequate temporary support is installed.
Load Bearing Wall Removal, clearly explained
Straight answers about calculations, approvals and starting the work.
How do I know if the wall is load bearing?
The direction of floor and roof members, walls above, foundations and the wider structural arrangement must be assessed. Visual appearance alone is not reliable.
Do I need Building Regulations approval?
Structural alterations normally require Building Regulations approval. The exact route should be confirmed for the property and work.
Can the beam be hidden in the ceiling?
Sometimes, but a flush beam can require deeper coordination with joists, connections, fire protection and construction access.
Will padstones be required?
They may be required where masonry bearing stress or load distribution is inadequate. The calculated beam reactions determine the support detail.
Do you provide installation drawings?
Yes. Structural details and relevant installation notes are included where agreed in the scope.
Choose the right engineering route
Ready to move your load bearing wall removal project forward?
Share the drawings, property details and intended work for a clear engineering scope.